AP-12.5Y Automatic Device for Multichannel Pipette Calibration

From:

The AP-12.5Y is designed to calibrate multichannel pipettes starting at 10 μl. The device features a readability [d] of 0.01 mg and can calibrate up to 12-channel fixed-volume and variable-volume pipettes.
Read full description and specs

SKU: WL-101-0416 Category:

Description

The AP-12.5Y is designed to calibrate multichannel pipettes starting at 10 μl. The device features a readability [d] of 0.01 mg and can calibrate up to 12-channel fixed-volume and variable-volume pipettes.

Because the pipette calibration on the AP-12.5Y is fully automatic, it is four times faster. On this instrument, calibrating a 12-channel pipette takes 1.5 hours instead of 6 hours.

 

The ergonomic design of the AP-12.5Y makes it possible to empty weighing vessels, and their overfilling is signalled by Ambient Light. Afour-channel pump is used to simultaneously remove water from four vessels, greatly reducing the time required for pipette calibration.

 

After emptying a 12-channel pipette, the AP-12.5Y checks all channels in a single cycle. In addition to a database of pipette calibration reports, the AP-12.5Y includes a database of pipettes that is editable and contains maximum permissible error values according to ISO 8655. The report database, in turn, contains measurements and error values calculated for individual points and volumes. The user determines the format and content of the reports.

 

The AP-12.5Y monitors the ambient conditions using calibrated sensors: THB P (ambient conditions measurement) and THB W (liquid temperature measurement), in accordance with ISO 8655. To calibrate the device with mass standards, the weighing pan must be replaced with a pan dedicated to checking and calibrating the balance (both are included in the standard equipment).

 

The AP-12.5Y can calibrate not only 12-channel pipettes, but also single-channel pipettes. Calibration of the single-channel pipette is possible thanks to an additional cover that replaces the case for 12-channel pipettes. The rest of the steps in the procedure remain the same.

TECHNICAL SPECIFICATIONS

Maximum capacity [Max] 52 g
Readability [d] 0.01 mg
Tare range -52 g
Standard repeatability [5% Max] 5 µg
Standard repeatability [Max] 10

 µg

Standard minimum weight (USP) 10 mg
Standard minimum weight (U=1%, k=2) 1 mg
Linearity ±0.03 mg
Stabilization time 4 s
Adjustment internal (automatic)

 

PICKUP AT AN NWI GROUP OFFICE LOCATION

If you don't want to pay for delivery or need to ASAP, you can pick the item up at one of our five (5) Australian offices. Just bear in mind not all offices will have everything in stock. Please ring our 1300 669 162 number to see if your item is in stock at your local office.

FREE DELIVERY

Most products are included in free delivery, however some are excluded as follows:

    • Orders and/or items under $299.
    • Orders and/or items that are deemed bulky, large or heavy.
    • Clearance items.
    • Orders that include or items that are classed as dangerous goods.

Remote areas are excluded from free delivery and you will either be charged delivery at checkout or may be contacted prior to delivery to confirm delivery charges if necessary.

INTERSTATE DELIVERIES

NWI Group reserve the right to change or withdraw free delivery at any time.

ESTIMATED DELIVERY TIMEFRAMES

If you opted to collect at a NWI office location you will receive an email to inform you when your goods are ready for collection.

If you opted for delivery, you will receive an email when the goods have been despatched to the couriers with details so you can track our order.

We aim to despatch all orders within 1-2 business days. In the unusual event of a delay to the despatch of your order you will be contacted at the earliest opportunity. Once the order has been despatched the estimated delivery time is as follows:

      • Metro (Excludes Hobart Metro) 1-2 business days
      • Hobart Metro 3-4 business days
      • Regional Areas 3-4 business days
      • Remote Areas 6-9 business days

Please note that these delivery timeframes are estimates and are not guaranteed.

RETURNS

Changed your mind? No worries. You just need to get the product back to the NWI office it was shipped from (this is on your receipt) within 30 days, unused and in its original packaging and we'll give you a refund (excluding delivery costs). Special order items are excluded from this returns policy.

 AP-12.5Y Datasheet ELLIPSIS 5Y Brochure EN

 

ABOUT US

Since inception in 1994, National Weighing and Instruments has been committed to providing a service of quality in the sale, repair and calibration of measuring equipment used in laboratories and manufacturing companies. Our strive for continuous improvement is part of our quality policy statement.

A family owned business, we have offices and agents throughout Australia. Our product range covers fine precision measuring equipment to large packaging and weighing machines, our calibration services for process and laboratories through our NATA accreditation guarantees our commitment to correct measurement and customer satisfaction.