Description
PM01.EX power supply comes in two designs:
- PM01.EX-1: power supply intended for operation in hazardous area:
- Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4.
- Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.
- PM01.EX-2: power supply intended for operation outside hazardous area, equipped with intrinsically safe circuits that can be placed in:
- Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4.
- Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.
PM02.EX power supply comes in two designs:
- PM02.EX-1-2: power supply intended for operation in hazardous area:
- Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4.
- Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.
- PM02.EX-2-2: power supply intended for operation outside hazardous area, equipped with intrinsically safe circuits that can be placed in:
- Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4.
- Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.
Technical Specifications
Physical parameters
Protection class | IP66 / IP68
|
Device dimensions | 216×174×64
mm |
ATEX Certification | II 2G Ex eb mb [ib] IIC T4 Gb II 2D Ex tb [ib] IIIC T70°C Db |
Working in zones | 1, 2 (gases); 21, 22 (dusts)
|
Power supply | 100 – 240 V AC 50/60 Hz
|
Power consumption max. | 15 W
|
Operating temperature | -20 — +40
°C |
Storage temperature | -20 — +60
°C |
Relative humidity | 10% — 85% RH no condensation
|
Housing | stainless steel |